Brocade Mobility Access Point System Reference Guide 215
53-1003100-01
5
FIGURE 102 Advanced Profile Configuration - MINT Protocol screen - Settings tab
Refer to the Area Identifier field to define the Level 1 Area IDs used by the profile’s MINT
configuration.
Define the following Device Heartbeat Settings in respect to devices supported by the profile:
Select the Latency of Routing Recalculation option (within the Shortest Path First (SPF) field) to
enable the spinner control used for defining a latency period from 0 - 60 seconds. The default
setting has the option disabled.
Level 1 Area ID
Select this option to enable a spinner control for setting the Level 1 Area ID from 1 -
4,294,967,295. The default value is disabled.
Designated IS Priority
Adjustment
Use the spinner control to set a Designated IS Priority Adjustment setting from -255 and 255.
This is the value added to the base level DIS priority to influence the Designated IS (DIS)
election. A value of +1 or greater increases DISiness. The default setting is 0.