122 Network OS Message Reference
53-1003227-01
CBR-1001
8
CBR Messages
CBR-1001
Message Port <port number> port fault. Change the SFP or check the cable.
Message Type LOG
Severity ERROR
Probable Cause Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.
Recommended
Action
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.
CBR-1002
Message Port <port number> chip faulted due to internal error.
Message Type LOG | FFDC
Severity ERROR
Probable Cause Indicates an internal error. All the ports on the interface module or switch will be disrupted.
Recommended
Action
For a modular switch, execute the power-off and power-on commands to power cycle the interface
module.
For a compact switch, reload or power cycle the switch.
Kommentare zu diesen Handbüchern