Brocade Network OS Message Reference v4.1.1 Bedienungsanleitung Seite 465

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 478
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 464
Network OS Message Reference 449
53-1003227-01
VCS-1007
8
VCS-1007
Message Event: VCS node remove, Coordinator IP: <Coordinator's Public IP>, VCS ID: <VCS
Id>, Status: rBridge ID <RBridge-id of Removed Switch> (<IP of Removed Switch>)
removed from VCS cluster.
Message Type LOG | VCS
Severity INFO
Probable Cause Indicates that VCS is disabled on the node that was part of a VCS cluster.
Recommended
Action
No action is required.
VCS-1008
Message Event: VCS node remove, Coordinator IP: <Coordinator's Public IP>, VCS ID: <VCS
Id>, Status: rBridge ID <RBridge-id of Switch That Failed To Be Removed> (<IP of
Switch That Failed To Be Removed>) failed removal from VCS cluster, Reason: <Error
Reason>.
Message Type LOG | VCS
Severity ERROR
Probable Cause Indicates that a logical-chassis node failed to be removed from the VCS cluster. Refer to the reason code
for the cause of the error.
Recommended
Action
Refer to reason code for possible action.
VCS-1009
Message Event: VCS node disconnect, Coordinator IP: <Coordinator's Public IP>, VCS ID:
<VCS Id>, Status: rBridge ID <RBridge-id of Switch That Disconnected> (<IP of
Switch That Disconnected >) disconnected from VCS cluster.
Message Type LOG | VCS
Severity INFO
Probable Cause Indicates that the heartbeat loss to a logical-chassis node occurred because the node was reloaded or all
interswitch links (ISLs) to the node are down.
Recommended
Action
If you had issued the reload command, no action is required. If for another reason, check the state of the
disconnected node and the ISLs to the disconnected node.
Seitenansicht 464
1 2 ... 460 461 462 463 464 465 466 467 468 469 470 ... 477 478

Kommentare zu diesen Handbüchern

Keine Kommentare