Network OS Message Reference 345
53-1003227-01
QOSD-1000
8
QOSD Messages
QOSD-1000
Message QoS initialized successfully.
Message Type LOG
Severity INFO
Probable Cause Indicates that the Data Center Ethernet (DCE) QoS has been initialized.
Recommended
Action
No action is required.
QOSD-1001
Message Failed to allocate memory: (<function name>).
Message Type LOG
Severity ERROR
Probable Cause Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check the memory usage on the switch using the show process memory command.
Restart or power cycle the switch.
QOSD-1005
Message QoS startup failed.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the Data Center Ethernet (DCE) QoS encountered an unexpected severe error during
basic startup and initialization.
Recommended
Action
Restart or power cycle the switch.
If the problem persists, download a new firmware version using the firmware download command.