200 Network OS Message Reference
53-1003227-01
FVCS-2002
8
FVCS-2002
Message Link State Update sent to Remote RBridge Failed - reason (<Failure Reason Code>).
Message Type LOG
Severity WARNING
Probable Cause Indicates a possible cluster infrastructure problem.
Recommended
Action
Execute the show fabric isl command to check the cluster connection status.
If the message persists, execute the copy support command and contact your switch service provider.
FVCS-2003
Message Lag Configureation Update sent to Remote RBridge Failed - reason (<Failure Reason
Code>).
Message Type LOG
Severity WARNING
Probable Cause Indicates a possible cluster infrastructure problem.
Recommended
Action
Execute the show fabric isl command to check the cluster connection status.
If the message persists, execute the copy support command and contact your switch service provider.
FVCS-2004
Message FCS Commit stage Failed - cfg type <Configuration Type>, cfg tag <Configuration
Tag>, domain <Source Domain>, reason (<Failure Reason Code>).
Message Type LOG
Severity WARNING
Probable Cause Indicates that the fabric configuration server (FCS) commit stage has failed. The failure reason can be
one of the following:
7 - Memory allocation error
14 - Reliable Transport Write and Read (RTWR) send failure
Recommended
Action
Check the status of the virtual link aggregation group (vLAG) identified by the configuration tag.
If the message persists, execute the copy support command on both this RBridge and the remote
RBridge specified by the domain field and contact your switch service provider.