304 Network OS Message Reference
53-1003227-01
NSM-1024
8
NSM-1024
Message RBridge ID <RBridgeId> has left Port-channel <PortChannelKey>. Port-channel is a
vLAG with RBridge IDs <RBridgeList>.
Message Type DCE
Severity INFO
Probable Cause Indicates that the specified RBridge has left the virtual link aggregation group (vLAG).
Recommended
Action
No action is required.
NSM-1025
Message RBridge ID <RBridgeId> has left Port-channel <PortChannelKey>. Port-channel has
only RBridge ID <RbridgeList> and is no longer a vLAG.
Message Type DCE
Severity INFO
Probable Cause Indicates that the virtual link aggregation group (vLAG) no longer exists.
Recommended
Action
No action is required.
NSM-1026
Message <SFPType> transceiver for interface <InterfaceName> is inserted.
Message Type DCE
Severity INFO
Probable Cause Indicates that a transceiver (SFP or CFP2) has been inserted in the specified interface.
Recommended
Action
No action is required.